1600 Boston-Providence Hwy Walpole, MA 02081
+1 866-956-5888
+1 866-956-5819

Evaluated Air Barrier Assemblies

Air Barrier Assemblies which have completed the ABAA Evaluation Process

Air Barrier Assemblies

Air barrier assemblies are divided into building assemblies for walls, roofs and foundations.  These broad heading, in some cases, are then sub-divided into specific types of walls, roofs and foundations.  Air barrier assemblies are made up of air barrier materials and connected with air barrier accessories.

Wall Air Barrier Assembly Evaluation

ABAA has set a maximum air leakage rate for wall air barrier assemblies as being 0.04 CFM/ft2 at a pressure difference of 1.57 lb./ft[0.20 L/(s·m2) at a pressure difference of 75 Pa] when tested in accordance with ASTM E 2357 Standard Test Method for Determining Air Leakage of Air Barrier Assemblies.

Scope of Evaluation

ABAA evaluations establish that the assembly tested passed a specified test.  Such evaluation does not constitute a product warranty and provides no prediction of useful life or future performance.

Get your air barrier material evaluated and listed with ABAA.

Get Evaluated

ABAA Evaluated Air Barrier Assemblies

Self Adhered Sheet Membranes Section 072713

Carlisle Coatings & Waterproofing www.carlisleccw.com

CCW-705
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0222 L/(s • m2) @ 75 Pa
[0.0044 cfm /ft2 @ 1.57 psf]
0.00 L/(s • m2) @ 75 Pa [0.000 cfm /ft2 @ 1.57 psf] 4.79 ng / Pa•s•m2 [0.083 US Perms] 5.47 ng / Pa•s•m2 [0.095 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Fire Resist 705 FR-A
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.007 L/(s • m2) @ 75 Pa
[0.0014 cfm /ft2 @ 1.57 psf]
0.00016 L/(s • m2) @ 75 Pa [0.000032 cfm /ft2 @ 1.57 psf] < 0.572 ng / Pa•s•m2 [[< 0.01 US Perms] < 0.572 ng / Pa•s•m2 [< 0.01 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Dörken Systems Inc. www.dorken.com

DELTA-VENT SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.039 L/(s • m2) @ 75 Pa
[0.0078 cfm /ft2@ 1.57 psf]
0.0015 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] 1763 ng / Pa•s•m2[30.9 US Perms]  2830 ng / Pa•s•m2[49.5 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

GCP Applied Technologies www.gcpat.com

Perm-A-Barrier® Wall Membrane
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.004 L/(s • m2) @ 75 Pa
[< 0.0008 cfm /ft2 @ 1.57 psf]
0.001 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] 2.58 ng / Pa•s•m2 [0.05 US Perms]  3.06 ng / Pa•s•m2 [0.05 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Henry Company www.henry.com

Blueskin® SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.006 L/(s • m2) @ 75 Pa
[0.0012 cfm /ft2 @ 1.57 psf]
0.0002 L/(s • m2) @ 75 Pa [0.00004 cfm /ft2 @ 1.57 psf] 2.0 ng / Pa•s•m2 [0.03 US Perms] 49.0 ng / Pa•s•m2 [0.86 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Huntsman Building Solutions www.huntsmanbuildingsolutions.com

Heatlok ABS
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa < 0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] 0.89 ng / Pa•s•m2 [0.016 US Perms] 1.8 ng / Pa•s•m2 [0.031 US Perms] Air Barrier Master Specification

SIGA americas.siga.swiss

Majvest 500 SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0041 L/(s • m2) @ 75 Pa
[0.00082 cfm /ft2 @ 1.57 psf]
0.0003 L/(s • m2) @ 75 Pa [0.00006 cfm /ft2 @ 1.57 psf] 882.59 ng / Pa•s•m2 [15.43 US Perms] 1620 ng / Pa•s•m2 [28.37 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Siplast www.siplast.com

WALLcontrolTM Reinforced Aluminum Butyl Adhered AWB
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.012 L/(s·m²) @ 75 Pa
[0.002 cfm/ft² @ 1.57 psf]
0.0009 L/(s·m²) @ 75 Pa
[0.0002 cfm/ft² @ 1.57 psf]
0.56 ng/Pa·s·m² [0.04 US Perms] 0.041 ng/Pa·s·m² [0.03 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

SOPREMAwww.soprema.us

SopraSEAL Stick 1100T
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa
[< 0.0004 cfm /ft2 @ 1.57 psf]
< 0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] 0.89 ng / Pa•s•m2 [0.016 US Perms] 1.8 ng / Pa•s•m2 [0.031 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

SopraSEAL STICK VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.005 L/(s • m2) @ 75 Pa
[< 0.001 cfm /ft2 @ 1.57 psf]
0.0024 L/(s • m2) @ 75 Pa [0.00048 cfm /ft2 @ 1.57 psf] 614 ng / Pa•s•m2 [10.7 US Perms] 978 ng / Pa•s•m2 [17.1 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Tremco www.tremcosealants.com

ExoAir® 110
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.1147 L/(s • m2) @ 75 Pa
[0.02294 cfm /ft2 @ 1.57 psf]
0.00005 L/(s • m2) @ 75 Pa [0.00001 cfm /ft2 @ 1.57 psf] 1.15 ng / Pa•s•m2 [0.02 US Perms] 1.26 ng / Pa•s•m2 [0.02 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

W.R. Meadows, Inc. www.wrmeadows.com

Air Shield
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0013 L/(s • m2) @ 75 Pa
[0.00026 cfm /ft2 @ 1.57 psf]
0.0015 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] 1.01 ng / Pa•s•m2 [0.018 US Perms] 2.697 ng / Pa•s•m2 [0.047 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification


Fluid Applied Membranes Section 072726

Ames Research Laboratorieswww.amesresearch.com

Blue Max® Liquid Applied Air Barrier™
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0041 L/(s • m2) @ 75 Pa
[0.00082 cfm /ft2 @ 1.57 psf] @ 30 mils dry
≤0.00001 L/(s • m2) @ 75 Pa [0.00010 cfm /ft2 @ 1.57 psf] @ 30 mils dry 6.67 ng / Pa•s•m2 [0.117 US Perms] @ 30 mils dry 28 ng / Pa•s•m2 [0.490 US Perms] @ 30 mils dry Air Barrier Construction Design Details

Air Barrier Master Specification

BASF Corporation – Construction Systemswww.master-builders-solutions.basf.us

MasterSeal® AWB 660 I (formerly Enershield I)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0055 L/(s • m2) @ 75 Pa
[0.0011 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0001 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 26 mils (wet) 5.53 ng / Pa•s•m2 [0.097 US Perms] @ 20 mils (wet) 377 ng / Pa•s•m2 [6.58 US Perms] @ 20 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

MasterSeal® AWB 660 (formerly Enershield HP)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0002 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10 mils (wet) 5.81 ng / Pa•s•m2 [0.10 US Perms] @ 10 mils (wet) 1004 ng / Pa•s•m2 [17.6 US Perms] @ 10 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

BASF Corporation – Wall Systemswww.wallsystems.basf.com

Senershield® VB
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0055 L/(s • m2) @ 75 Pa
[0.0011 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0001 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 26 mils (wet) 5.53 ng / Pa•s•m2 [0.097 US Perms] @ 20 mils (wet) 377 ng / Pa•s•m2 [6.58 US Perms] @ 20 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Finestop® VB
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0055 L/(s • m2) @ 75 Pa
[0.0011 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0001 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 26 mils (wet) 5.53 ng / Pa•s•m2 [0.097 US Perms] @ 20 mils (wet) 377 ng / Pa•s•m2 [6.58 US Perms] @ 20 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Senershield® R
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0002 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10 mils (wet) 5.81 ng / Pa•s•m2 [0.10 US Perms] @ 10 mils (wet) 1004 ng / Pa•s•m2 [17.6 US Perms] @ 10 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Acrostop® R
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0002 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10 mils (wet) 5.81 ng / Pa•s•m2 [0.10 US Perms] @ 10 mils (wet) 1004 ng / Pa•s•m2 [17.6 US Perms] @ 10 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Finestop® RA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils wet
0.0002 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10 mils (wet) 5.81 ng / Pa•s•m2 [0.10 US Perms] @ 10 mils (wet) 1004 ng / Pa•s•m2 [17.6 US Perms] @ 10 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Carlisle Coatings & Waterproofingwww.carlisleccw.com

Barriseal-S/R
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.012 L/(s • m2) @ 75 Pa
[0.00242 cfm /ft2 @ 1.57 psf] @ 65 mils (wet)
0.0065 L/(s • m2) @ 75 Pa [0.0013 cfm /ft2 @ 1.57 psf] @ 46 mils (wet) 9.411 ng / Pa•s•m2 [0.1647 US Perms] @ 46 mils (dry) 48.745 ng / Pa•s•m2 [0.853 US Perms] @ 46 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Barritech VP/ Barritech VP LT
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.025 L/(s·m²) @ 75 Pa [0.000) cfm/ft² @ (1.56 lb/ft²) @ 45 mils (wet) 0.000001 L/(s·m²) @ 75 Pa [0.0000002 cfm/ft² @(1.56 lb/ft²] @ 45 wet mils (wet) 41.1 ng / Pa•s•m2 [0.719 US Perms] @ 60 mils (wet) [40 mils (dry)] 817 ng / Pa•s•m2 [14.295 US Perms] @ 60 mi ls (wet) [40 mils (dry)] Air Barrier Construction Design Details

Air Barrier Master Specification

Barrithane VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0041 L/(s • m2) @ 75 Pa
[0.00082 cfm /ft2 @ 1.57 psf] @ 15 – 25 mils (wet)
0.000003 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] @    15 – 25 mils (wet) 943.22 ng / Pa•s•m2 [16.49 US Perms] @ 20 mils (dry) 1692.54 ng / Pa•s•m2 [29.59 US Perms] @ 20 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Fire-Resist Barritech NP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.1167 L/(s • m2) @ 75 Pa
[0.0230 cfm /ft2 @ 1.57 psf] @ 80 mils (wet)
0.001 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] @ 80 mils (wet) [40 mils (dry)] 2.86 ng / Pa•s•m2 [0.05 US Perms] @ 35 mils (dry) 44 ng / Pa•s•m2 [0.77 US Perms] @ 35 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Dow Performance Siliconewww.buildabetterbarrier.com

DefendAir 200
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.00049 L/(s • m2) @ 75 Pa
[0.000098 cfm /ft2 @ 1.57 psf] @ 28 – 34 mils (dry)
0.0049 L/(s • m2) @ 75 Pa [0.00098 cfm /ft2 @ 1.57 psf] @ 15 mils (dry) 402.11 ng / Pa•s•m2 [7.03 US Perms] @ 15 mils (dry) 1387.7 ng / Pa•s•m2 [24.26 US Perms] @ 15 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

DuPont Performance Building Solutionswww.dupont.com

Tyvek® Fluid Applied WB +
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.001 L/(s • m2)
[0.0002 cfm /ft2 @ 1.57 psf] @ 25 dry mil
0.0008 L/(s • m2) @ 75 Pa [0.00016 cfm /ft2 @ 1.57 psf] @ 24 mils (dry) 687.96 ng / Pa•s•m2 [11.8 US Perms] @ 25 mils (dry) 1269.84 ng / Pa•s•m2 [22.2 US Perms] @ 25 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

GCP Applied Technologies www.gcpat.com

PERM-A-BARRIER® NPL 10
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0102 L/(s • m2) @ 75 Pa
[0.00204 cfm /ft2 @ 1.57 psf] @ 70 mils [wet]
0.0002 L/(s • m2) @ 75 Pa [0.00004 cfm /ft2 @ 1.57 psf] @ 43 mils [dry] 6.4 ng / Pa•s•m2 [0.11 US Perms] @ 40 mils [dry] 26 ng / Pa•s•m2 [0.461 US Perms] @ 40 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

PERM-A-BARRIER® VPL 50RS UV Stable
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0782 L/(s • m2) @ 75 Pa
[0.01564 cfm /ft2 @ 1.57 psf] @ 20 mils (dry)
0.0008 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] @ 23 mils (dry) 635 ng / Pa•s•m2 [11.1 US Perms] @ 25 mils (wet) 964 ng / Pa•s•m2 [16.9 US Perms] @ 25 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

PERM-A-BARRIER® VPL and VPL/LT
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.009 L/(s • m2) @ 75 Pa
[0.0007 cfm /ft2 @ 1.57 psf] @ 25 mils (dry)
0.0003 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] @ 25 mils (dry) 69 ng / Pa•s•m2 [1.2 US Perms] @ 23 mils (dry) 1168 ng / Pa•s•m2 [20.4US Perms] @ 25 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Georgia-Pacificwww.buildgp.com

DensDefy™ Liquid Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.009 L/(s • m2) @ 75 Pa
[0.000546 cfm /ft2 @ 1.57 psf] @ 15 mils (wet)
0.0007 L/(s • m2) @ 75 Pa [0.00014 cfm /ft2 @ 1.57 psf] @ 18 mils (wet) 547 ng / Pa•s•m2 [9.6 US Perms] @ 15 mils (dry)  797 ng / Pa•s•m2 [13.9 US Perms] @ 15 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Henry Companywww.henry.com

Air-Bloc® 16MR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0505 L/(s • m2) @ 75 Pa
[0.01 cfm /ft2 @ 1.57 psf] @ 59 mils [dry]
0.0013 L/(s • m2) @ 75 Pa [0.00026 cfm /ft2 @ 1.57 psf] @ 54 mils [dry] 10.6 ng / Pa•s•m2 [0.185 US Perms] @ 60 mils [dry] 66.1 ng / Pa•s•m2 [1.156 US Perms] @ 60 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Bloc® 17MR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.004 L/(s • m2) @ 75 Pa
[0.0008 cfm /ft2 @ 1.57 psf] @ 40 mils [wet]
<0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] @ 40 mils [wet] 97.7 ng / Pa•s•m2 [1.708 US Perms] @ 21.4 mils [dry] 706.8 ng / Pa•s•m2 [12.356US Perms] @ 21.4 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Bloc® 31MR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.004 L/(s • m2) @ 75 Pa
[0.0008 cfm /ft2 @ 1.57 psf] @ 90 mils wet
0.0012 L/(s • m2) @ 75 Pa [0.00024 cfm /ft2 @ 1.57 psf] @ 87 mils (wet) 32.0 ng / Pa•s•m2 [0.57 US Perms] @ 44 mils (dry) 2066 ng / Pa•s•m2 [36.12 US Perms] @ 44 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Bloc® 32MR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0029 L/(s • m2) @ 75 Pa
[0.00058 cfm /ft2 @ 1.57 psf] @ 75 – 115 mils wet
0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] @ 118 mils (wet) 13.0 ng / Pa•s•m2 [0.23 US Perms] @ 118 mils (wet) 58 ng / Pa•s•m2 [1.02 US Perms] @ 118 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Bloc® 33MR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0071 L/(s • m2) @ 75 Pa
[0.0014 cfm /ft2 @ 1.57 psf] @ 100 mils (wet) [58 mils (dry)]
0.0008 L/(s • m2) @ 75 Pa [0.0016 cfm /ft2 @ 1.57 psf] 19.0 ng / Pa•s•m2 [0.34 US Perms] @ 59 mils (dry) 652 ng / Pa•s•m2 [11.4 US Perms] @ 59 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Bloc® All Weather STPE
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0209 L/(s • m2) @ 75 Pa
[0.0042 cfm /ft2 @ 1.57 psf] @ +/-20 mils [dry]
0.0055 L/(s • m2) @ 75 Pa [0.0011 cfm /ft2 @ 1.57 psf] @ 23 mils [dry] 620.8 ng / Pa•s•m2 [10.85 US Perms] @ 13.31 mils [dry] 1002 ng / Pa•s•m2 [17.52 US Perms] @ 13.22 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

Hohmann & Barnard, Incwww.h-b.com

Enviro-Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0040 L/(s • m2) @ 75 Pa
[0.0008 cfm /ft2 @ 1.57 psf] @ 50 mils (wet)
0.0004 L/(s • m2) @ 75 Pa [0.00008 cfm /ft2 @ 1.57 psf] @ 40 mils (dry) 3.40 ng / Pa•s•m2 [0.060 US Perms] @ 40 mils (dry) 39.6 ng / Pa•s•m2 [0.694 US Perms] @ 40 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Karnak Corporationwww.karnakcorp.com

321 K-NRG Seal VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.010 L/(s • m2) @ 75 Pa
[0.002 cfm /ft2 @ 1.57 psf] @ 24 mils (dry)
0.00006 L/(s • m2) @ 75 Pa [0.00012 cfm /ft2 @ 1.57 psf] @ 16 mils (dry) 133.8ng / Pa•s•m2 (2.34 US Perms) @ 16 mils (dry) 1584.4ng / Pa•s•m2 (27.7 US Perms) @ 16 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Kemper System America Inc.www.kemper-system.com

Wall Guardian® FW-100 Asphaltic-component
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa
[< 0.00043 cfm /ft2 @ 1.57 psf] @ 60 mils wet [35 mils dry]
0.0069 L/(s • m2) @ 75 Pa [0.001358 cfm /ft2 @ 1.57 psf] at 30 mils (dry) [60 mils (wet)] < 5.72 ng / Pa•s•m2 [< 0.10 US Perms] @ 30 mils (dry) 720 ng / Pa•s•m2 [12.6 US Perms] @ 30 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Wall Guardian® FW-100-A Acrylic Based
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa
[0.0004 cfm /ft2 @ 1.57 psf] @ 20 mils dry
0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] at 20 mils (dry) 55.3 ng / Pa•s•m2 [0.96 US Perms] @ 22 mils (dry) 661 ng / Pa•s•m2 [11.5 US Perms] @ 22 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Laticretewww.laticrete.com

Air and Water Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0017 L/(s • m2) @ 75 Pa
[0.0003 cfm /ft2 @ 1.57 psf] @ 63 mils (dry)
0.00052 L/(s • m2) @ 75 Pa [0.000104 cfm /ft2 @ 1.56 psf] @ 38 mils (wet) [25 mils (dry)] 4.92 ng / Pa•s•m2 [0.086 US Perms] @ 35 mils (wet) [25 mils (dry)] 57.3 ng / Pa•s•m2 [1.002 US Perms] @ 36 mils (wet) [26 mils (dry)] Air Barrier Construction Design Details

Air Barrier Master Specification

Master Wall Inc.www.masterwall.com

Rollershield
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.003 L/(s • m2) @ 75 Pa
[0.0006 cfm /ft2 @ 1.57 psf] @ 10 mils (dry)
0.001 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] @ 26 mils (dry) 311.74 ng / Pa•s•m2 (5.45 US Perms) @ 5 mils (dry) 1944 ng / Pa•s•m2 (34.43 US Perms) @ 5 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Momentivewww.siliconeforbuilding.com

GE Elemax 2600
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0009 L/(s • m2) @ 75 Pa
[0.0018 cfm /ft2 @ 1.57 psf] @ 19 mils (wet)
0.003 L/(s • m2) @ 75 Pa [0.0006 cfm /ft2 @ 1.57 psf] @ 17 mils (dry) 453.02 ng / Pa•s•m2 (7.92 US Perms) @ 17 mils (dry) 581.15 ng / Pa•s•m2 (10.16 US Perms) @ 17 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Pecora Corpationwww.pecora.com

ProPerm VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.01 L/(s • m2) @ 75 Pa
[0.002 cfm /ft2 @ 1.57 psf] @ 16 mils [wet]
0.000004 L/(s • m2) @ 75 Pa [0.0000008 cfm /ft2 @ 1.57 psf] @ 13 mild [dry] 217.36 ng / Pa•s•m2 [3.8 US Perms] @ 10 mild [dry] 1229 ng / Pa•s•m2 [21.5 US Perms] @ 10 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

XL-PermULTRA NP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.01672 L/(s • m2) @ 75 Pa
[0.0033 cfm /ft2 @ 1.57 psf] @ 20 mils [wet]
0.0001 L/(s • m2) @ 75 Pa [0.00002 cfm /ft2 @ 1.57 psf] @ 16 mil [dry] 19.448 ng / Pa•s•m2 [0.34 US Perms] @ 12 mils (dry) 32.032 ng / Pa•s•m2 [0.56 US Perms] @ 12 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

XL-PermULTRA VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0040 L/(s • m2) @ 75 Pa
[0.0008 cfm /ft2 @ 1.57 psf] @ 14 mils (wet)
0.0012 L/(s • m2) @ 75 Pa [0.00024 cfm /ft2 @ 1.57 psf] @ 12 mils (dry) 766.48 ng / Pa•s•m2 (13.4 US Perms) @ 9 mils (dry) 1332.76 ng / Pa•s•m2 (23.3 US Perms) @ 9 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Polyglass®www.polyglass.us

VertiWrap™ NPL
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.006 L/(s • m2) @ 75 Pa
[0.0013 cfm /ft2 @ 1.57 psf] @ 32 mils (wet)
0.00492 L/(s • m2) @ 75 Pa [0.000097 cfm /ft2 @ 1.57 psf] @ 40 mils (wet) 6.699 ng / Pa•s•m2 [0.117 US Perms] @ 19.3 mils (dry) 857 ng / Pa•s•m2 [15 US Perms] @ 19.7 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

VertiWrap™ NPL LT / Vertiwrap NPL LT VOC
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.005 L/(s • m2) @ 75 Pa
[0.0009 cfm /ft2 @ 1.57 psf] @ 32 mils (wet)
0.002 L/(s • m2) @ 75 Pa [0.0004 cfm /ft2 @ 1.57 psf] @ 40+ mils (wet) 0.751 ng / Pa•s•m2 [0.0.13 US Perms] @ 20 mils (dry) 6.29 ng / Pa•s•m2 [0.11 US Perms] @ 12 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

VertiWrap™ VPL
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.003 L/(s • m2) @ 75 Pa
[0.0013 cfm /ft2 @ 1.57 psf] @ 25 mils (dry)
0.002 L/(s • m2) @ 75 Pa [0.0004 cfm /ft2 @ 1.57 psf] @ 25 mils (dry) 56 ng / Pa•s•m2 [0.97 US Perms] @ 25 mils (dry) 971 ng / Pa•s•m2 [17 US Perms] @ 25 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

PROSOCO, Inc.www.prosoco.com

R-Guard Cat 5™ / R-Guard Cat 5™ Rain Screen
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.009 L/(s • m2) @ 75 Pa
[0.0028 cfm /ft2 @ 1.57 psf] @ 15 mils [wet]
0.0007 L/(s • m2) @ 75 Pa
[0.00014 cfm /ft2 @ 1.57 psf] @ 18 mils [wet]
547ng / Pa•s•m2 [9.6 US Perms] @ 15 mils [dry] 797 ng / Pa•s•m2 [13.9 US Perms] @ 15 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

R-Guard Cat 5™ ICF
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0107 L/(s • m2) @ 75 Pa
[0.0021 cfm /ft2 @ 1.57 psf] @ 12 – 16 mils wet]
0.0009 L/(s·m²) @ 75 Pa
[0.00018 cfm/ft² @ 1.57 lb/ft²] @ 12mils (dry)
859 ng/Pa·s·m2 [15.03 US Perms] @ 12 – 15 mils (wet) 1015 ng/Pa·s·m2 [17.71 US Perms] @ 12 – 15 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

R-Guard Spray Wrap MVP / R-Guard Spray Wrap Rain Screen
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0028 L/(s • m2) @ 75 Pa
[0.0059 cfm /ft2 @ 1.57 psf] @ 10 mils [wet]
0.0024 L/(s • m2) @ 75 Pa
[0.00048 cfm /ft2 @ 1.57 psf] @ 10 mils [wet]
154.44 ng / Pa•s•m2 [2.7 US Perms] @ 10 mils [wet] 1430 ng / Pa•s•m2 [25 US Perms] @ 10 mils [wet] Air Barrier Construction Design Details

Air Barrier Master Specification

CavityComplete® AWRB (www.cavitycomplete.com)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0107 L/(s • m2) @ 75 Pa
[< 0.0021 cfm /ft2 @ 1.57 psf] @ 12 – 16 mils (wet)
0.0009 L/(s • m2) @ 75 Pa [0.00018 cfm /ft2 @ 1.56 psf] @ 12 mils (dry) 859 ng / Pa•s•m2 (15.03 US Perms) @ 12-15 mils (wet) 1015 ng / Pa•s•m2 (17.71 US Perms) @ 12-15 mils (wet) CAD files:

Guide specs:

Sika Corp.www.sika.com

Sikagard® 520 Liquid Applied Vapor Permeable Air Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa
[< 0.00043 cfm /ft2 @ 1.57 psf] @ 60 mils (wet) [35 mils (dry)]
0.0069 L/(s • m2) @ 75 Pa [0.0014 cfm /ft2 @ 1.57 psf] @ 30 mils (dry) < 5.7 ng / Pa•s•m2 (< 0.1 US Perms) @ 30 mils (dry) 720 ng / Pa•s•m2 (12.6 US Perms) @ 30 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Sikagard® 530 Liquid Applied Vapor Permeable Air Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0022 L/(s • m2) @ 75 Pa
[< 0.00043 cfm /ft2 @ 1.57 psf] @ 20 mils (dry)
0.0005 L/(s • m2) @ 75 Pa [< 0.0001 cfm /ft2 @ 1.57 psf] @ 20 mils (dry) 55.3 ng / Pa•s•m2 (0.96 US Perms) @ 22 mils (dry) 661 ng / Pa•s•m2 (11.5 US Perms) @ 22 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Sikagard® 535 Liquid Applied Vapor Permeable Air Barrier
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.013 L/(s • m2) @ 75 Pa
[0.0026 cfm /ft2 @ 1.57 psf] @ 20 mils dry
0.0009 L/(s • m2) @ 75 Pa [0.00018 cfm /ft2 @ 1.57 psf] @ 10 mils dry 108 ng / Pa•s•m2 [1.9 US Perms] @ 20 mils dry 351 ng / Pa•s•m2 [6.1 US Perms] @ 20 mils dry Air Barrier Construction Design Details

Air Barrier Master Specification

SOPREMAwww.soprema.us

SOPRASEAL LM 202 VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils (wet)
0.0002 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10 mils (wet) 5.81 ng / Pa•s•m2 (0.10 US Perms) @ 10 mils (wet) 1004 ng / Pa•s•m2 (17.6 US Perms) @ 10 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

SOPRASEAL LM 203
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0066 L/(s • m2) @ 75 Pa
[0.00132 cfm /ft2 @ 1.57 psf] @ 10 mils (wet)
0.0001 L/(s • m2) @ 75 Pa [0.00002 cfm /ft2 @ 1.57 psf] @ 26 mils (wet) 5.53 ng / Pa•s•m2 (0.097 US Perms) @ 20 mils (wet) 377 ng / Pa•s•m2 (6.58 US Perms) @ 20 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

SOPRASEAL LM 204 VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0020 L/(s • m2) @ 75 Pa
[0.0004 cfm /ft2 @ 1.57 psf] @ 36 mils [wet]
0.0017 L/(s • m2) @ 75 Pa [0.00034 cfm /ft2 @ 1.57 psf] @ 20 mils [dry] 903.86 ng / Pa•s•m2 [15.8 US Perms] @ 20 mils [dry] 1384.24 ng / Pa•s•m2 [24.2 US Perms] @ 20 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

Sto Corp.www.stocorp.com

EmeraldCoat
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0008 L/(s • m2) @ 75 Pa
[0.00016 cfm /ft2 @ 1.57 psf] @ 10 mils (wet)
0.00020 L/(s • m2) @ 75 Pa [0.00024 cfm /ft2 @ 1.57 psf] @ 20 mils (dry) 121.26 ng / Pa•s•m2 (2.12 US Perms) @ 12 mils (dry) 797.94 ng / Pa•s•m2 (13.95 US Perms) @ 12 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

StoPanel AWRB 81835
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.016 L/(s • m2) @ 75 Pa
[0.00311 cfm /ft2 @ 1.57 psf] @ 10 – 20 mils (wet)
0.000 L/(s • m2) @ 75 Pa [0.0000 cfm /ft2 @ 1.57 psf] @ 10-12 mils (wet) 6.86 ng / Pa•s•m2 (0.12 US Perms) @ 12 mils (wet) 202 ng / Pa•s•m2 (3.54 US Perms) @ 12 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

Gold Fill
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.012 L/(s • m2) @ 75 Pa
[0.00227 cfm /ft2 @ 1.57 psf] @ 32 – 63 mils
0.0014 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] 107 ng / Pa•s•m2 (1.87 US Perms) @ 27 mils (wet) 480 ng / Pa•s•m2 (8.40 US Perms) @ 30 mils (wet) Air Barrier Construction Design Details

Air Barrier Master Specification

VaporSeal
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.011 L/(s • m2) @ 75 Pa
[0.00215 cfm /ft2 @ 1.57 psf] @ 32 – 48 mils (wet)
0.01623 L/(s • m2) @ 75 Pa [0.004 cfm /ft2 @ 1.56 psf] @ 32 – 48 mils (wet) 2.52 ng / Pa•s•m2 (0.044 US Perms) @ 30 mils (dry) 32.6 ng / Pa•s•m2 (0.57 US Perms) @ 26 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

TK Productswww.tkproducts.com

TK-AirMax 2102 (Non-Permeable), TK-AirMax 2102 (Non-Permeable VOC)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.005 L/(s • m2) @ 75 Pa
[0.0009 cfm /ft2 @ 1.57 psf] @ 32 mils wet
0.002 L/(s • m2) @ 75 Pa [0.0004 cfm /ft2 @ 1.57 psf] @ 40+ mils (wet) 0.751 ng / Pa•s•m2 [0.013 US Perms] @ 20 mils (dry) 6.29 ng / Pa•s•m2 [0.11 US Perms] @ 12 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

TK-AirMax 2103 (Water-Based)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.006 L/(s • m2) @ 75 Pa
[0.0013 cfm /ft2 @ 1.57 psf] @ 32 mils wet
0.00492 L/(s • m2) @ 75 Pa [0.00097 cfm /ft2 @ 1.57 psf] @ 40 mils (wet) 6.699 ng / Pa•s•m2 [0.117 US Perms] @ 19.3 mils (dry) 857 ng / Pa•s•m2 [15.0 US Perms] @ 19.7 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

TK-AirMax 2104 (Water Base)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.024 L/(s • m2) @ 75 Pa
[0.0047 cfm /ft2 @ 1.57 psf] @ 32 mils wet [22 mils dry]
0.004 L/(s • m2) @ 75 Pa [0.0008 cfm /ft2 @ 1.57 psf] @ 40+ mils (wet) 17.1 ng / Pa•s•m2 [0.3 US Perms] @ 12.1 mils (dry) 1007 ng / Pa•s•m2 [17.6 US Perms] @ 14 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Tremcowww.tremcosealants.com

ExoAir® 130
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.029 L/(s • m2) @ 75 Pa
[0.0058 cfm /ft2 @ 1.57 psf] @ 80 mils [wet]
< 0.0005 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] @ 40 mils [dry] 25 ng / Pa•s•m2 [0.44 US Perms] @ 37 mils [dry] 145 ng / Pa•s•m2 [2.48 US Perms] @ 35.4 mils [dry] Air Barrier Construction Design Details

Air Barrier Master Specification

ExoAir® 230
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
[0.01 cfm /ft2 @ 1.57 psf] @ 35 mils dry 0.00011 L/(s • m2) @ 75 Pa [0.00030 cfm /ft2 @ 1.57 psf] @ 40 mils (wet) 103.72 ng / Pa•s•m2 [1.81 US Perms] @ 29 mils (dry) 1677 ng / Pa•s•m2 [29.31 US Perms] @ 29 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

W.R. Meadows, Inc.www.wrmeadows.com

Air-Shield LM
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0032 L/(s • m2) @ 75 Pa
[0.00064 cfm /ft2 @ 1.57 psf] @ 45 mils
0.003 L/(s • m2) @ 75 Pa [0.0006 cfm /ft2 @ 1.57 psf] @ 45 mils 8.25 ng / Pa•s•m2 [0.144 US Perms] @ 45 mils (dry) 8.64 ng / Pa•s•m2 [0.227 US Perms] @ 45 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Shield LMP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0038 L/(s • m2) @ 75 Pa [0.0008 cfm /ft2 @ 1.57 psf] @ 60 mils (wet) [30 mils dry] 0.0042 L/(s • m2) @ 75 Pa [0.0008 cfm /ft2 @ 1.57 psf] @ 30 mils (dry) 17.84 ng / Pa•s•m2 [0.312 US Perms] @ 43.4 mils (dry) 720.14 ng / Pa•s•m2 [12.59 US Perms] @ 40.5 mils (dry) Air Barrier Construction Design Details

Air Barrier Master Specification

Air-Shield LSR
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.00085 L/(s • m2) @ 75 Pa
[0.00017 cfm /ft2 @ 1.57 psf] @ 71 mils (dry)
0.00094 L/(s • m2) @ 75 Pa
[0.00019 cfm /ft2 @ 1.57 psf] @ 69 mils (dry)
9.09 ng/Pa s m2    [0.159 US Perms @32 mils (dry)] 63.72 ng/Pa s m2 [1.144 US Perms @ 34 mils (dry)] Air Barrier Construction Design Details

Air Barrier Master Specification


Sprayed Polyurethane Foam (Medium Density Closed Cell) Section 072703

Barnhardt Manufacturing Company dba NCFI Polyurethaneswww.ncfi.com

InsulStar®, InsulBloc®
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0032 L/(s • m2) @ 75 Pa
[0.00064 cfm /ft2 @ 1.57 psf] @ 37mm [1.5″]
0.0003 L/(s • m2) @ 75 Pa [0.00005 cfm /ft2 @ 1.57 psf] @ 25mm [1″] 56 ng / Pa•s•m2 [0.97 US Perms] @ 20mm [0.80″] 134 ng / Pa•s•m2 [2.35 US Perms] @ 20mm [0.80″] Air Barrier Construction Design Details

Air Barrier Master Specification

BASFwww.spf.basf.com

Walltite
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0076 L/(s • m2) @ 75 Pa
[0.0015 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″]
0.00032 L/(s • m2) @ 75 Pa [0.000064 cfm /ft2 @ 1.57 psf] @ 32mm [1.3″] 79.6 ng / Pa•s•m2 [1.39 US Perms] @ 25mm [1.0″] 241 ng / Pa•s•m2 [4.22 US Perms] @ 25mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

Carlisle Spray Foam Insulationwww.carlislesfi.com

SealTite Pro Closed Cell
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0213 L/(s • m2) @ 75 Pa
[0.0043 cfm /ft2 @ 1.57 psf] @ 39mm [1.5″]
0.00011 L/(s • m2) @ 75 Pa [0.00023 cfm /ft2 @ 1.57 psf] @ 25mm [1″] 34.5 ng / Pa•s•m2 [0.603 US Perms] @ 33mm [1.3″] 56 ng / Pa•s•m2 [0.979 US Perms] @ 50mm [2.0″] Air Barrier Construction Design Details – Coming Soon

Air Barrier Master Specification

CertainTeed Corporationwww.certainteed.com

CertaSpray CC
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.008 L/(s • m2) @ 75 Pa
[0.0016 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″]
0.00076 L/(s • m2) @ 75 Pa [0.000152 cfm /ft2 @ 1.57 psf] @ 27mm [1.06″] 56 ng / Pa•s•m2 [0.98 US Perms] @ 36mm [1.42″] 102 ng / Pa•s•m2 [1.79 US Perms] @ 47mm [1.85″] Air Barrier Construction Design Details

Air Barrier Master Specification

Henry Companywww.henry.com

Permax 2.0
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.0025 L/(s • m2) @ 75 Pa
[< 0.00049 cfm /ft2 @ 1.57 psf] @ 50mm [2.0″]
0.0005 L/(s • m2) @ 75 Pa [0.000098 cfm /ft2 @ 1.57 psf] 27 ng / Pa•s•m2 [0.472 US Perms] @ 52.8mm [2.078″] 84 ng / Pa•s•m2 [1.46 US Perms] @ 63.5mm [2.5″] Air Barrier Construction Design Details

Air Barrier Master Specification

Huntsman Building Solutionswww.huntsmanbuildingsolutions.com

Foam-Lok AB2000
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0915 L/(s • m2) @ 75 Pa
[0.0183 cfm /ft2 @ 1.57 psf] @ 37mm [1.5″]
0.000244 L/(s • m2) @ 75 Pa [0.000049 cfm /ft2 @ 1.57 psf] @ 50mm [2.0″] 49 ng / Pa•s•m2 [0.8 US Perms] @ 50mm [1.97″] 90 ng / Pa•s•m2) [1.58 US Perms) @ 50mm [2.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

Heatlok® Soy 200 Plus
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0022 L/(s • m2) @ 75 Pa
[0.00044 cfm /ft2 @ 1.57 psf] @ 100mm [4.0″]
0.004 L/(s • m2) @ 75 Pa [0.0008 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″] 1.131 US Perms @ 25mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

Heatlok® HFO
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.001 L/(s • m2) @ 75 Pa
[0.002 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″]
< 0.0001 L/(s • m2) @ 75 Pa [<0.0001 cfm /ft2 @ 1.57 psf] @ 25mm [2.0″] 53.98 ng / Pa•s•m2 [0.94 US Perms] @ 25mm [1.0″] 67.07 ng / Pa•s•m2 [1.17 US Perms] @ 25mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

Heatlok® XT
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0383 L/(s • m2) @ 75 Pa
[0.0076 cfm /ft2 @ 1.57 psf] @ 50mm [2.0″]
0.020 L/(s • m2) @ 75 Pa [0.004 cfm /ft2 @ 1.57 psf] @ 25mm 70.5 ng / Pa•s•m2 [1.23 US Perms] @ 25mm 119 ng / Pa•s•m2 [2.08 US Perms] @ 25mm Air Barrier Construction Design Details

Air Barrier Master Specification

MD-C-200
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0803 L/(s • m2) @ 75 Pa
[0.0161 cfm /ft2 @ 1.57 psf] @ 50mm [2.0″]
0.0008 L/(s • m2) @ 75 Pa [0.00016 cfm /ft2 @ 1.57 psf] @ 52mm [2.05″] 50.6 ng / Pa•s•m2 [0.884 US Perms] @ 37mm [1.5″] 2748 ng / Pa•s•m2 [48.09 US Perms] @ 50mm [2.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

ProSeal (MD-C-200-v3)
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0106 L/(s • m2) @ 75 Pa
[0.00212 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″]
0.00150 L/(s • m2) @ 75 Pa [0.00030 cfm /ft2 @ 1.57 psf] @ 32 mm [1.29″] 68.9 ng / Pa•s•m2 [1.205 US Perms] @ 25mm [1.0″] 74 ng / Pa•s•m2 [1.3 US Perms] @ 50mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

Johns Manvillewww.specjm.com

Corbond III
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0915 L/(s • m2) @ 75 Pa
[0.0183 cfm /ft2 @ 1.57 psf] @ 37mm [1.5″]
0.000244 L/(s • m2) @ 75 Pa [0.000049 cfm /ft2 @ 1.57 psf] @ 50mm [2.0″] 53 ng / Pa•s•m2 [0.927 US Perms] @ 50mm [2.0″] 120 ng / Pa•s•m2 [2.0 US Perms] @ 25mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

SES Polyurethane Systemswww.sesfoam.com

Nexseal™ 2.0
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.001 L/(s • m2) @ 75 Pa
[0.0002 cfm /ft2 @ 1.57 psf] @ 25mm [1.0″]
0.0031 L/(s • m2) @ 75 Pa [0.00062 cfm /ft2 @ 1.57 psf] @ 25 mm [1.0″] 38.3 ng / Pa•s•m2 [0.669 US Perms] @ 50mm [2.0″] 127 ng / Pa•s•m2 [2.2 US Perms] @ 25mm [1.0″] Air Barrier Construction Design Details

Air Barrier Master Specification

SWD Urethanewww.swdurethane.com

QUIK-SHIELD 112 XC
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0188 L/(s • m2) @ 75 Pa
[0.00376 cfm /ft2 @ 1.57 psf] @ 50 mm [2.0″]
0.001 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] @ 26mm [1.0″] 65.62 ng / Pa•s•m2 [1.15 US Perms] @ 50mm [2.0″] 145.86 ng / Pa•s•m2 [2.550 US Perms] @ 50mm [2.0″] Air Barrier Construction Design Details

Air Barrier Master Specification


Mechanically Fastened Commercial Building Wrap Section 072708

Berry Globalwww.typar.com

METROWRAP™
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.185 L/(s • m2) @ 75 Pa
[0.0364 cfm /ft2 @ 1.57 psf]
0.0013 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] 471.27 ng / Pa•s•m2 [8.239 US Perms] N/A Air Barrier Construction Design Details

Air Barrier Master Specification

Typar® DrainableWrap ™ Commercial
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.08 L/(s • m2) @ 75 Pa
[0.0157 cfm /ft2 @ 1.57 psf]
0.0013 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] 471.27 ng / Pa•s•m2 [8.239 US Perms] N/A Air Barrier Construction Design Details

Air Barrier Master Specification

DuPont Performance Building Solutionswww.dupont.com

Tyvek® CommercialWrap®
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.05 L/(s • m2) @ 75 Pa
[0.01 cfm /ft2 @ 1.57 psf]
0.0023 L/(s • m2) @ 75 Pa [0.00046 cfm /ft2 @ 1.57 psf] 1446 ng / Pa•s•m2 [25.31 US Perms]  1867 ng / Pa•s•m2 [32.68 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Tyvek® CommercialWrap® D
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0803 L/(s • m2) @ 75 Pa
[0.0158 cfm /ft2 @ 1.57 psf]
0.00225 L/(s • m2) @ 75 Pa [0.00045 cfm /ft2 @ 1.57 psf] 2437 ng / Pa•s•m2 [42.65 US Perms]  2427 ng / Pa•s•m2 [42.48 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification


Boardstock – Rigid Cellular Thermal Insulation Board Section 072723

DuPont Performance Building Solutionswww.dupont.com

Styrofoam Ultra SL
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.02072 L/(s • m2) @ 75 Pa
[0.004144 cfm /ft2 @ 1.57 psf] @ 1.75″ [44mm] thick foam sheathin
0.0012 L/(s • m2) @ 75 Pa [0.00023 cfm /ft2 @ 1.57 psf] @ 1.0″ [25mm] thick foam sheathing <62.9 ng / Pa•s•m2 [<1.1 US Perms] @ 1.0″ [25mm] thick foam sheathing  

Air Barrier Construction Design Details

Air Barrier Master Specification

Thermax Wall System
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.05 L/(s • m2) @ 75 Pa
[0.01 cfm /ft2 @ 1.57 psf] @ 5/8″ [16mm] thick foam sheathing
0.001 L/(s • m2) @ 75 Pa [0.0002 cfm /ft2 @ 1.57 psf] @ 1/2″ [13mm] thick foam sheathing 2.29 ng / Pa•s•m2 [0.04 US Perms] @ 1.0″ [25mm] thick foam sheathing Air Barrier Construction Design Details

Air Barrier Master Specification

Ultra Wall Air Barrier System
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0803 L/(s • m2) @ 75 Pa
[0.01606 cfm /ft2 @ 1.57 psf] @ 1.5″ [38mm] thick foam sheathing
0.0012 L/(s • m2) @ 75 Pa [0.00023 cfm /ft2 @ 1.57 psf] @ 1.0″ [25mm] thick foam sheathing <62.9 ng / Pa•s•m2 [<1.1 US Perms] @ 1.0″ [25mm] thick foam sheathing Air Barrier Construction Design Details

Air Barrier Master Specification

Johns Manvillewww.specjm.com

AP Foil-Faced
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0064 L/(s • m2) @ 75 Pa
[0.00128 cfm /ft2 @ 1.57 psf] @ 1.0″ [25mm] thick foam sheathing
0.0007 L/(s • m2) @ 75 Pa [0.00013 cfm /ft2 @ 1.57 psf] @ 1.0″ [25mm] thick foam sheathing 3 ng / Pa•s•m2 [0.06 US Perms] @ 1.0″ [25mm] thick foam sheathing Air Barrier Construction Design Details

Air Barrier Master Specification

Rmaxwww.rmax.com

ECOMAXci Wall Solution
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0462 L/(s • m2) @ 75 Pa
[0.000924 cfm /ft2 @ 1.57 psf] @ 3/4″
0.00049 L/(s • m2) @ 75 Pa [0.0001 cfm /ft2 @ 1.57 psf] @ 3/4″ 0.88 ng / Pa•s•m2 [0.02 US Perms] @ 2″  10 ng / Pa•s•m2 [0.2 US Perms] @ 3/4″ Air Barrier Construction Design Details – Method 1

Air Barrier Construction Design Details – Method 2

Air Barrier Master Specification


Factory-Bonded Membranes to Sheathing ABAA Model Spec currently in development

Georgia-Pacificwww.buildgp.com

Dens Element Barrier System
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0802 L/(s • m2) @ 75 Pa
[0.01604 cfm /ft2 @ 1.57 psf]
0.00510 L/(s • m2) @ 75 Pa [0.00086 cfm /ft2 @ 1.57 psf] – 5/8th board 1,459 ng / Pa•s•m2 [25.5 US Perms] – 5/8th board  1,850 ng / Pa•s•m2 [32.327 US Perms] – 5/8th board Air Barrier Construction Design Details

Air Barrier Master Specification

SOPREMAwww.soprema.us

Sopraseal Xpress G
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.038 L/(s • m2) @ 75 Pa
[0.0076 cfm /ft2 @ 1.57 psf]
0.00834 L/(s • m2) @ 75 Pa [0.001668 cfm /ft2 @ 1.57 psf] 1.22 ng / Pa•s•m2 [0.0214 US Perms]  1.10 ng / Pa•s•m2 [0.0193 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Tremcowww.securockexoair.com

Securock ExoAir® 430 System
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.02 L/(s • m2) @ 75 Pa
[< 0.004 cfm /ft2 @ 1.57 psf]
0.0001 L/(s • m2) @ 75 Pa [< 0.00002 cfm /ft2 @ 1.57 psf] 105.24 ng / Pa•s•m2 [1.84 US Perms]  279.70 ng / Pa•s•m2 [4.89 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification


Adhesive Backed Commercial Building Wrap ABAA Model Spec currently in development

Dörken Systems Inc.www.dorken.com

DELTA-VENT SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.039 L/(s • m2) @ 75 Pa
[0.0078 cfm /ft2 @ 1.57 psf]
0.0015 L/(s • m2) @ 75 Pa [0.0003 cfm /ft2 @ 1.57 psf] 1763 ng / Pa•s•m2 [30.9 US Perms] 2830 ng / Pa•s•m2 [49.5 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

GCP Applied Technologieswww.gcpat.com

PERM-A-BARRIER® NPS Wall Membrane
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0117 L/(s • m2) @ 75 Pa
[0.00234 cfm /ft2 @ 1.57 psf]
0.0002 L/(s • m2) @ 75 Pa [0.00004 cfm /ft2 @ 1.57 psf] 0.4 ng / Pa•s•m2 [0.007 US Perms] 0.5 ng / Pa•s•m2 [0.008US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

PERM-A-BARRIER® VPS 30
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
<0.2 L/(s • m2) @ 75 Pa
[0.04 cfm /ft2 @ 1.57 psf]
<0.02 L/(s • m2) @ 75 Pa [0.004 cfm /ft2 @ 1.57 psf] 480 ng / Pa•s•m2 [8.4 US Perms] 519 ng / Pa•s•m2 [8.46 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Polyglass®www.polyglass.us

VertiWrap™ NPS
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.00157 L/(s • m2) @ 75 Pa
[0.00314 cfm /ft2 @ 1.57 psf]
0.00016 L/(s • m2) @ 75 Pa [0.00032 cfm /ft2 @ 1.57 psf] 34.89 ng / Pa•s•m2 [0.61 US Perms] 14.35 ng / Pa•s•m2 [0.251 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

VertiWrap™ VPS
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.0279 L/(s • m2) @ 75 Pa
[0.00558 cfm /ft2 @ 1.57 psf]
0.00028 L/(s • m2) @ 75 Pa [0.00056 cfm /ft2 @ 1.57 psf] 415.84 ng / Pa•s•m2 [7.27 US Perms] 829.4ng / Pa•s•m2 [14.5 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

SOPREMAwww.soprema.us

SopraSEAL STICK VP
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
< 0.005 L/(s • m2) @ 75 Pa
[< 0.001 cfm /ft2 @ 1.57 psf]
0.0024 L/(s • m2) @ 75 Pa [0.00048 cfm /ft2 @ 1.57 psf] 614 ng / Pa•s•m2 [10.7 US Perms] 978 ng / Pa•s•m2 [17.1 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Tremcowww.tremcosealants.com

ExoAir 210AT
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
0.063 L/(s • m2) @ 75 Pa
[0.0126 cfm /ft2 @ 1.57 psf]
0.003 L/(s • m2) @ 75 Pa [0.0006 cfm /ft2 @ 1.57 psf] 556 ng / Pa•s•m2 [9.9 US Perms] 825.53 ng / Pa•s•m2 [14.43 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

Vaproshieldwww.vaproshield.com

REVEALSHIELD SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
<0.01 L/(s • m2) @ 75 Pa
[<0.01 cfm /ft2 @ 1.57 psf]
0.0001 L/(s • m2) @ 75 Pa [0.00002 cfm /ft2 @ 1.57 psf] 1600 ng / Pa•s•m2 [28.07 US Perms] 3630 ng / Pa•s•m2 [63.48 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

WRAPSHIELD SA
Test Results
Air Leakage Rate of Wall Assembly (ASTM E2357) Air Leakage Rate of Material (ASTM E2178) Water Vapor Permeance (ASTM E96 – desiccant method) Water Vapor Permeance (ASTM E96 – water method) Details & Specs
<0.01 L/(s • m2) @ 75 Pa
[<0.01 cfm /ft2 @ 1.57 psf]
0.0001 L/(s • m2) @ 75 Pa [0.00002 cfm /ft2 @ 1.57 psf] 1630 ng / Pa•s•m2 [28.46 US Perms] 2510 ng / Pa•s•m2 [43.85 US Perms] Air Barrier Construction Design Details

Air Barrier Master Specification

 

If you have any questions about Evaluated Air Barrier Assemblies please contact the ABAA office by email at abaa@airbarrier.org or by phone at 866-956-5888.